consultant@extendmax.vn024 6666 3066
  • Tiếng Việt
  • English

QCVN 55:2023/BTTTT on RF for NFC and 2kHz - 30MHz SRD and inductive loop devices

QCVN 55:2023/BTTTT National technical regulation on Short Range Device (SRD) - Radio Equipment to be used in the 9kHz to 30MHz frequency range. Enforced from 01-July-2024.

EXTENDMAX – On February 09, 2023, the Ministry of Information and Communications announced the draft circular promulgated together with QCVN 55:2023/BTTTT National technical regulation on Short Range Device (SRD) - Radio Equipment to be used in the 9kHz to 25MHz frequency range. The draft QCVN 55:2023/BTTTT is compiled based on ETSI EN 300 330 V2.1.1 (2017-02) standard but also includes 26,957 ÷ 27,283 MHz frequency range from FCC Part 15 Subpart C. The QCVN 55:2023/BTTTT has been officially released together with MIC Circular 17/2023/TT-BTTTT on 27-Nov-2023 and taking effect from 01 July 2024, be compulsory for import procedures, quality inspection, certification of conformity, and declaration of conformity from 01 July 2024 for NFC and 9kHz - 30MHz SRD and inductive loop devices.

QCVN-55-2023-BTTTT-RF-NFC-SRD-9kHz-30Mhz

Insights of the QCVN 55:2023/BTTTT

Application scope of QCVN 55:2023/BTTTT

QCVN 55:2023/BTTTT applies to NFC and 9kHz - 30MHz SRD and inductive loop devices with operating frequency ranges and HS code and product description as below.

Operating frequency range

Table 1 - Operating frequency range allowed to be used for SRD within 9kHz ~ 30MHz frequency range

 

 

Frequency band / frequency

Application

Tx and Rx

9 ÷ 90 kHz

Inductive loop device, used for generic application

Tx and Rx

90 ÷ 119 kHz

Inductive loop device, used for generic application

Tx and Rx

119 ÷ 140 kHz

Inductive loop device, used for generic application 

Tx and Rx

140 ÷ 148,5 kHz

Inductive loop device, used for generic application

Tx and Rx

148,5 ÷ 190 kHz

Inductive loop device, used for generic application

Tx and Rx

3,155 ÷ 3,400 MHz

Inductive loop device, used for generic application 

Tx and Rx

3,234 ÷ 5,234 MHz

Inductive loop device, used in traffic applications

Tx and Rx

6,765 ÷ 6,795 MHz

Inductive loop device, used for generic application 

Tx and Rx

10,200 ÷ 11,000 MHz

Inductive loop device, used for generic application

Tx and Rx

13,553 ÷ 13,567 MHz

Inductive loop device, used for generic application

Tx and Rx

26,957 ÷ 27,283 MHz

Inductive loop device, used for generic application

 

Annex J

HS Codes of short-range radio equipment and magnetic loop equipment in the frequency range 9 kHz - 30 MHz

TT

Product name according to the QCVN

HS codes

Product description

 

Short range radio transmitters and transceivers for general purposes

8517.62.59

8517.62.69

Equipment with an external antenna connector and/or with an integrated antenna, intended for the transmission or reception of voice, images or other data; including devices using active NFC (Near Field Communication) technology.

2.              

Radio detection and alarm equipment

8526.92.00

Device consisting of a sensor and a control system interconnected via a radio interface for radio detection and alarm purposes

3.              

Radio remote control equipment

8526.92.00

Equipment using radio waves to control models, or remote control in industrial and civil applications.

4.              

Radio Frequency Identification Device (RFID)

8517.62.59

The device uses radio waves to automatically identify, track, manage goods, people, animals and other applications. The device has two separate units connected via a radio interface:

- Radio transceivers, which store information in the form of an electronic chip tag (RF tag), mounted on the object to be identified; Only applies to RF tag with power source.

- Radio transceiver (RF Reader) to activate the RF tag and receive the tag's information, forward to the data processing system.

5.              

Inductive loop device

8504.40.19

8504.40.90

Short-range radio equipment operating on the principle of electromagnetic fields, including:

- Radio Frequency Identification Device

- Device using Near Field Communication technology

- Equipment used in the Electronic Article Surveillance (EAS) gate system operates in the LF and HF

 

New points of QCVN 55:2023/BTTTT

Compared to QCVN 55:2011/BTTTT (current version), QCVN 55:2023/BTTTT has the following basic new points.

1) Applicable scope extended from 9kHz ~ 25MHz up to 9kHz ~ 30MHz and include ISM band 26,957 ÷ 27,283 MHz.

2) MIC add HS code of SRD products which is under mandatory applicable scope

Taking effect date of the QCVN 55:2023/BTTTT

Based on the draft circular promulgating regulations, it is expected that QCVN 55:2023/BTTTT will take effect from 01 July 2024 and be mandatory in the same day.

Insight from ExtendMax regarding QCVN 55:2023/BTTTT

→ Accordingly, the products having NFC or SRD 125kHz transmitting functions or other short-range-device shall need to apply to obtain MIC Type Approval certificate with QCVN 55:2023/BTTTT standard. Typical products under its mandatory scope are smart phones, SRDs used in vehicle, 125kHz RFID, etc...

Down load the QCVN 55:2023/BTTTT and Circular 17/2023/TT-BTTTT regulations: https://mic.gov.vn/van-ban-phap-luat/14928.htm 

Contact information for market access requirements consulting

EXTENDMAX VIETNAM COMPANY LIMITED

Hotline: +84 915 836 555 | Hanoi: +84 24 6666 3066

Email: consultant@extendmax.vn | phuong.tran@extendmax.vn

HO: ExtendMax Villa, C01-L18 An Vuong, Duong Noi urban area, Duong Noi ward, Ha Dong district, Hanoi City, Vietnam

Test laboratory: BT02-21, An Hung urban area, To Huu street, La Khe ward, Ha Dong district, Hanoi City, Vietnam

 

If you find our article useful and valuable in practice applications, please support us by rating it, leaving your comment at the bottom of this article, and sharing it with your colleagues or the industry. Your review will be a great motivation for us to write more detailed and valuable procedural guides for importing, exporting organizations.

↓ ↓ ↓ ↓ ↓ ↓ ↓

Customer ratings
5.0
5
0%
4
0%
3
0%
2
0%
1
0%

Share product reviews

Rate and comment

Send your comment

      Comment
      Submit a comment
      Comment
        News Post
        Contact now

        EXTENDMAX VIETNAM COMPANY LIMITED

        Tax Code: 0106943741

        Email: consultant@extendmax.vn

        Hot line: +84 915 836 555 | Hanoi: +84 24 6666 3066

        Consulting CCP License: +84 915 836 555

        Reg. Add:P903, 9F, Tower A, Sky City Tower Complex, 88 Lang Ha street, Lang Ha ward, Dong Da district, Hanoi city, Vietnam

        HO: ExtendMax Villa, C01-L18 An Vuong, Duong Noi ward, Ha Dong, Hanoi, Vietnam

        Test Lab: BT02-21, An Hung urban area, To Huu street, La Khe ward, Ha Dong, Hanoi, Vietnam