logo


Email: consultant@extendmax.vn
Hotline: +84 915 836 555 | HCMC: +84 28 7303 8868 | Hanoi: +84 24 6666 3088
HO: Villa BT02-21, An Hung urban area, To Huu str., Duong Noi ward, Ha Dong dist., Hanoi, Vietnam
HCMC Branch: 1F, Kicotrans Bld., No.5 Dong Da str., Ward 2, Tan Binh dist., Ho Chi Minh City, Vietnam
Test laboratory: Villa BT02-21, An Hung urban area, To Huu, Duong Noi, Ha Dong dist., Hanoi, Vietnam

Lựa chọn ngôn ngữ:
Select your language:

MIC released draft 2020 version of technical regulations on RF requirement for 2.4GHz Wi-Fi, Zigbee and 1GHz ~ 40GHz SRD

  26/04/2020

MIC has released draft new versions of technical regulations on RF requirement for 2.4GHz Wi-Fi, Zigbee and 1GHz ~ 40GHz SRD - QCVN 54:2020/BTTTT and QCVN 74:2020/BTTTT for public comments

1. Test limits and test methods:

QCVN 54:2020/BTTTT is equivalent to ETSI EN 300 328 v2.2.2 (2019-07)

QCVN 74:2020/BTTTT is equivalent to ETSI EN 300 440 V2.2.1(2018-07)

2. Major Impacts:

(1) All test report according to former version QCVN 54:2011/BTTTT or QCVN 74:2013/BTTTT shall not be accepted for type approval certification. Customer need to re-test according to 2020 version

(2) All Type Approval certificate which list QCVN 54:2011/BTTTT or QCVN 74:2013/BTTTT need to be renewed or add-in QCVN 54:2020/BTTTT / QCVN 74:2020/BTTTT to maintain validity for importation

(3) MRA labs need to apply for MIC MRA recognition according to new standards in order to get test reports accepted by MIC Vietnam for the new standards

(4) MRA test report must be at least according to ETSI EN 300 328 v2.2.2 (2019-07) or ETSI EN 300 440 V2.2.1(2018-07) version in order to be accepted for TA certification. MRA test report according to former versions shall be rejected.

(5) Impacted product categories:

5.1 Impacted by QCVN 54:2020/BTTTT: 

All the products which has Wi-Fi or Zigbee  (Laptop, tablet, mobile phone, access point, Wi-Fi router, other kind of product having Wi-Fi connection, smarthome Zigbee products...)

5.2 Impacted by QCVN 74:2020/BTTTT: 

SRD operated in 1GHz – 40GHz bands like 2.4GHz RFID / SRD, 24 GHz radar… (except for Wi-Fi, BT, Zigbee or other kinds of product which a more specific technical regulation has been applied) 

Both draft national technical regulations QCVN 54:2020/BTTTT and QCVN 74:2020/BTTTT are aimed to be implemented at 01 July 2021 and impacts shall be enforced on the same day. MIC will list the new versions QCVN 54:2020/BTTTT and QCVN 74:2020/BTTTT on the new circular to regulate list of products under mandatory TA and SDoC (similar to Circular 05/2019/TT-BTTTT) which shall be issued on around March or April 2021

Comment

News

View all

Contact info

  • EXTENDMAX VIETNAM COMPANY LIMITED
  • Tel: +84 24 6666 3088;
  • Email: consultant@extendmax.vn
  • Head Office: Villa BT02-21, An Hung urban area, To Huu str., La Khe ward, Ha Dong dist., Hanoi, Vietnam
  • HCMC Branch: 1F, Kicotrans building, No.5 Dong Da street, Ward 2, Tan Binh district, Ho Chi Minh City, Vietnam
  • Test laboratory: Villa BT02-21, An Hung urban area, To Huu str., La Khe ward, Ha Dong dist., Hanoi, Vietnam
TAKING EFFECT SOON