Email: consultant@extendmax.vn
Tel: +84 24 32 032 032 | Hotline: +84 915 836 555
HO: 9F, Nam Cuong building, Km4 To Huu street, La Khe ward, Ha Dong district, Hanoi, Vietnam
HCMC Branch: 1F, Kicotrans Bld., No.5 Dong Da str., Ward 2, Tan Binh dist., Ho Chi Minh City, Vietnam

Lựa chọn ngôn ngữ:
Select your language:

MIC Guidance No. 2902/BTTTT-KHCN for implementation of Circular 05/2019/TT-BTTTT

  28/08/2019

Updated on August 29, 2019: MIC officer-in-charge has confirmed although HS Code and product description match product listed under item 3.1 and 3.8 of Appendix I of Circular 05/2019/TT-BTTTT, Bluetooth / Zigbee / 2.4GHz wireless having RF power under 60mW shall still be exempted due to remark (**) at bottom of Appendix I of Circular 05/2019/TT-BTTTT

(**) Short-range radio transmitters, transceivers are stipulated in Circular no.46/2016/TT-BTTTT dated December 26th, 2016 issued by MIC on regulate the list of license-free frequency bands for radio devices, amended and supplemented by Circular no.18/2018/TT-BTTTT dated December 20th, 2018. Short-range devices do not include receiver; Radio equipment operating in the 2.4 GHz band and using spread spectrum modulation techniques with EIRP power less than 60mW; Radio access equipment operating in the 5 GHz band with EIRP power less than 60 mW. Type Approval certification and Declaration of Conformity shall be allowed if the device meet the requirement of frequency range and exploiting accordingly.

On August 28, 2019, MIC Vietnam has released Guidance letter No. 2902/BTTTT-KHCN application and implementation of Circular No. 05/2019/TT-BTTT.

Key features:

1. MIC confirm CISPR 32:2015 test report (issued by designated local test lab or oversea labs recognized by MIC Vietnam) can replace report according to QCVN 118:2018/BTTTT. This feature has been foreseen by ExtendMax from December of 2018 and we have helped customers to obtain local CISPR 32:2015 report (instead of TCVN 7189:2009), saving re-testing cost for hundreds of PCs, laptop PCs, tablets

2. For laptops, notebooks, or tablets imported at small quantity, importer may ask permission to use test report issued by oversea ISO/IEC 17025 accredited test laboratory for declaration of conformity of lithium battery to complete Product Quality Inspection Registration (PQIR) procedure.

3. MIC continues to allow test item under extreme test conditions can be covered by declaration of conformity on product datasheet or test report issued by oversea ISO/IEC 17025 accredited test laboratory

4. MIC continues to allow test report for DVB-T2 chassis/platform can be used for declaration of conformity for DVB-T2 smart TiVi.

5. MIC re-confirms that only test report issued by designated local test laboratory or oversea test laboratory recognized by MIC Vietnam under MRA can be used for declaration of conformity for lithium battery (for formal cases, not including special cases mentioned under item 4)

6. For certain standards (which are mostly applicable for marine transceiver and transmitter), MIC allows to use test reports issued by manufacturer or oversea ISO / IEC 17025 accredited test laboratories for conformity certification and declaration of conformity.

Key impacts:

→ A few marine radios which has been allowed to use oversea report before, now is required to obtain local test report or report issued by MRA labs.

Please find the original Guidance letter No. 2902/BTTTT-KHCN and English translation version below:

 

Tags:

Comment

News

View all

Contact info

  • EXTENDMAX VIETNAM COMPANY LIMITED
  • Tel: +84 24 32 009 753
  • Email: consultant@extendmax.vn
  • Head Office: 9F, Nam Cuong building, Km4 To Huu street, La Khe ward, Ha Dong district, Hanoi City, Vietnam
  • HCMC Branch: 1F, Kicotrans building, No.5 Dong Da street, Ward 2, Tan Binh district, Ho Chi Minh City, Vietnam